Description
Item Type: Battery Monitor_x000D_
Model: KL110F_x000D_
Material: ABS_x000D_
Application: For electric power value detection. _x000D_
Control Method: APP on Mobile Phone_x000D_
ModelKL110F_x000D_
Sampling MethodSampler_x000D_
Voltage Measurement Range (Externally Powered)0~120V_x000D_
Voltage Measurement Range (Self Powered)10V~120V_x000D_
Voltage Resolution0.01V_x000D_
Current Measurement Range0~100A_x000D_
Current Resolution0.1A_x000D_
RelayNo relay is provided, you need to configure it yourself._x000D_
Temperature Measurement Range-20~120_x000D_
Capacity Display Range0%~100%_x000D_
Power Measurement Range0~72KW_x000D_
Power Resolution0.01W_x000D_
Ampere Hour Measuring Range0~9999.99AH_x000D_
Volume Resolution0.001AH_x000D_
Watt Hour Measurement Range0~9999.99kWH_x000D_
Watt Hour Resolution0.01WH_x000D_
Bluetooth Communication Distance (Approx.)Barrier free up to 10m / 32.81ft._x000D_
Voltage Accuracy2%+3 Digit_x000D_
Current Accuracy5%+10 Digit_x000D_
Sampling Rate1 time/sec_x000D_
Measuring Board Power ConsumptionAbout 0.4W_x000D_
Over Power Protection0~99999.99W_x000D_
Negative Over Current Protection0~50A, 100A, 400A, 600A_x000D_
Positive Over Current Protection0~50A, 100A, 400A, 600A_x000D_
Over Voltage Protection0~120V, 600V_x000D_
_x000D_
1. Mobile Phone Control:_x000D_
A. Instructions for The Use of for Android Mobile APP: The software only supports the use of for Android 5.0 and systems above. During the installation, it will apply for location services. Please agree and turn on location services. This user manual corresponds to software version 1.0, and different versions may be slightly different. It is recommended to upgrade to the latest software for a better user experience. _x000D_
B. Instructions for Use of for iPhone Mobile APP: The software only supports for iPhone 9.0 and systems above. The first time the software connects to Bluetooth, it will access Bluetooth. Please agree to access. This manual corresponds to software version 1.0, and different versions may be slightly different. It is recommended to upgrade to the latest software for a better user experience. You can get the latest software from the for iPhone Store, and the for iPhone software version corresponding to the current manual is 1.0. _x000D_
2. Wiring:_x000D_
A. Self Powered Wiring Mode: If the voltage range of the battery under test is between 10-120V, the self powered wiring can be used. First, turn the power supply selection interface switch to 2W, and then connect the positive terminal of the battery to the interface Vsns of power supply , this line does not need to be particularly thick, 1-2.5mm2 lines can be used, be careful not to connect the positive terminal of the battery incorrectly. The negative terminal of the battery is connected to the screw marked with the battery GND marks on the sampler. The negative ple of the charger and the negative pole of the load are connected to another screw of the sampler together. It is better to use a copper standoff to wire it firmly. When charging, the current colour on the mobile phone APP is green, and the remaining capacity value increases. When discharging, the current colour is sky blue, and the remaining capacity value decreases. _x000D_
B. External Power Supply Wiring Method: The voltage range of external power supply measurement is 0-120V. First, turn the power supply selection interface switch to 3W, connect the positive pole of the external power supply to the power supply interface VEXT, and the negative pole of the external power supply to GND. Then connect the positive terminal of the battery to the measurement interface Vsns in the power supply interface when wiring. Be careful not to connect the positive and negative poles of the external power supply incorrectly or in reverse. The negative terminal of the battery is connected to the screw marked with the battery GND marks on the sampler, and the negative pole of the charger and the negative pole of the load are connected to another screw of the sampler together. The current colour is green, the remaining capacity value increases, and the current colour is sky blue during discharge, and the remaining capacity value decreases._x000D_
C. Connection Method of External Power Supply to Relay: The working power of the relay is provided by the external power supply. If the relay is connected, an external power supply with the same working voltage as the relay must be provided. Connect the control ports of the relay to the OUT and VEXT of the output control of the measurement module respectively, connect the positive pole of the external power supply to the VEXT of the Output Control, and the negative pole of the external power supply to GND. Be careful not to connect the positive and negative terminals of the battery and external power supply wrongly or reversely. When the relay is closed, the indicator ligh
-
Fruugo ID:
309946242-693561182
-
EAN:
925985463742
Product Safety Information
Please see the product safety information specific to this product outlined below
The following information is provided by the independent third-party retailer selling this product.
Safety Warnings:
Do not let your children touch this product alone to avoid swallowing or other injuries.
Delivery & Returns
Dispatched within 3 days
Shipping from China.
We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy